- Product ubrs: title
- Detection of protein residues on surfaces and in solutions
- Fast, simple, and reliable test results
- Rapid test for the detection of specific allergens
Why can't I see prices?
Log in to view your prices or request a quote. Or request an account and we will contact you as soon as possible.
- Product ubrs: title
- Detection of protein residues on surfaces and in solutions
- Fast, simple, and reliable test results
- Rapid test for the detection of specific allergens
Product description
NEOGEN L25MLK Cow's milk allergen rapid test for the detection of whole cow's milk proteins. Suitable for residue in CIP rinse water, environmental samples, food ingredients, and processed foods. This complete allergen Rapid Kit comes with 25 tests and accessories.
- Allergen rapid test for the detection of whole cow's milk proteins.
- For the testing of CIP rinse water, food samples, or environmental samples.
- Suitable for testing food ingredients and processed foods.
- This rapid test is supplied as a complete kit, including accessories.
- Results are obtained within 12 minutes.
- Uses lateral flow (lateral flow device - LFD).
- Rapid flow test cassettes for the detection of allergenic food proteins.
- In the event of a positive test result, three lines are visible.
- Contains 25 tests, extraction buffer solution, and 26 dilution tubes.
- Preferably store the NEOGEN whole cow's milk rapid tests at 2 to 8 °C.
- Intended exclusively for professional and trained personnel.
- Widely used within the food and beverage industry. A professional and widely used protein test within the food and beverage industry. Results are obtained within just 12 minutes. This reliable test method utilizes a 'lateral flow device' (LFD), an immunochromatographic method that employs antibodies specific for the detection of cow's milk protein. Positive results are indicated by the presence of three lines: a control line, a marker line, and a test line, if milk protein is present equal to or higher than 3 ppm for raw materials, processed food products, and CIP or rinse water solution, and above 2.5 g/mL per 100 cm² for surfaces. These threshold values may vary depending on the matrix tested. Samples containing more than 3% milk may result in an invalid test, which is indicated by the absence of the marker line and/or test line.
The dynamic range of the NEOGEN Rapid Cow's Milk Protein Set has been demonstrated at 1.25 ppm and 100,000 ppm of cow's milk. The highest limit has been demonstrated at approximately 1.5 mg/mL of NISTa 1549 in distilled water.
The NEOGEN Cow's Milk Total Protein Rapid Test is intended exclusively for professional and trained personnel. In case of doubt or uncertainty, always consult a specialist. Read more about exact use and application in the user manual.
Contents of this test kit
- Whole cow's milk protein Lateral Flow Device (25 x individually packed)
- Dilution tubes (26 x Microcentrifuge tube 2.2 ml)
- Extraction buffer (1 x bottle 50 ml)
Specifications
Productspecificaties
| Brand | NEOGEN |
| Article ID | L25MLK |
| Type | Allergen Rapit Kit |
| Product Group | Allergen tests |
| Type of allergen | Whole cow's milk protein |
| System | Lateral flow device (LFD) |
| Content | Complete kit |
| Number of tests | 25 pieces |
| Extraction buffer content | 50 ml (bottle) |
| Number of dilution tubes | 26 pieces |
| Storage advice | 2 to 8 °C (store in a dry place) |
| Shelf life | 24 months (ex works) |
| Detection Limit (LOD) | 3 ppm |
| Packaging unit | Box of 25 tests |